Connection
StecaGrid 9000 3phInverter for grid feedingAlways symmetricalThe advantage of three-phase feeding is that the produced solar capacity is always symmetrically distributed on all three power conductors to the public power grid. This is the case across the whole output range offered by StecaGrid 9000 3ph. When designing a system, the laborious avoidance of an asymmetry of more than 4.6 kW through the appropriate selection of separate inverters is thus dispensed with. Symmetrical feeding is greatly in the interests of energy supply companies. Lengthy discussions with such companies are therefore a thing of the past. Long service liveWhile the voltage passes through zero on the grid-feeding phase, single-phase inverters must temporarily accommodate all energy supplied by the solar modules within the device. This is usually realised by electrolytic capacitors. These components influence the service life of an electronic device, due to the possibility of drying out. With three-phase inverters, energy is fed into the grid on at least two phases at all times. Thus, the necessity of intermediate storage of energy in the device is greatly reduced, which is of benefit to the system operator with regard to a longer service life. Flexible connectionDue to the wide input voltage range of 350 V to 800 V, and a maximum input current of 32 A, all commonly available crystalline solar modules can be connected to the StecaGrid 9000 3ph in various configurations. Beyond this, the system is also approved for use with CdTe and CIS / CIGS thin-film modules. Five plug/socket pairs are available for flexible, mechanical DC connection. Easy handlingDespite its high output, the StecaGrid 9000 3ph is a wall-mounted device. Thanks to the high degree of protection, this inverter can be installed indoors or outdoors. Due to the integrated DC circuit breaker, installation work is made easier, and the installation time is reduced. It is not necessary to open the StecaGrid 9000 3ph during installation. Guarantee serviceThe StecaGrid 9000 3ph comes with a 5-year guarantee as standard. The guarantee period can be optionally extended up to 10 years. | ![]()
|
Product features
| Electronic protection functions
Displays
Options
|
Advantage of three-phase feeding
Power curve P shows the power fed in to the public electricity grid. The grey shaded area shows the energy
to be stored in the inverter. The advantage of three-phase feeding is plain to see.


StecaGrid 9000 3ph connection
StecaGrid 9000 3ph grid inverters and Meteocontrol WEB'log: